Magnizon-Smart Online Rack/Tower Mount UPS, 1000VA/1000W

MU1000RM2U

Overview

Magnizon MU1000RM2U 1000VA / 1000 watt Smart online, double-conversion UPS system offers complete power protection for critical applications. True online, double-conversion technology supports the critical loads with zero transfer time(0mSec), suitable for advanced networking applications. Fault-tolerant Static-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Elegant LCD display with vast scope of monitoring and setting up of various paraments make UPS tailored for each specific application.

Key Features

  • Magnizon MU1000RM2U 1KVA/1000W smart on-line, double-conversion UPS system in 2U total rack/tower configuration
  • Maintains full-time pure sine wave output within 2% of selectable 220/230/240V nominal during brownouts as low 110V and over voltages as high as 300V
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Online double conversion technology with advanced DSP control
  • Wide input voltage range(110?300VAC) can adapt to different power grid environment
  • DC start (cold start) function
  • Input PFC filters
  • Built-in static bypass switches
  • Input power factor 1.0 and unity Output power factor
  • Strong over load capacity
  • Supporting rack/tower structure, high power density saving space
  • Built-in protections: Over voltage, Over load, Over current, Battery overcharge, Battery deep discharge protection, battery low voltage protection
  • LCD display and LED indicator show detailed UPS status and parameters
  • Friendly man-machine interface, Simple setting Output Voltage, Frequency parameter and Bypass function on the display
  • Lightning, surge, short -circuit, network/fax/modem surge protection
  • Smart RS232 communication with monitoring software
  • Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
  • Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
  • Supports 50/60Hz operation for worldwide frequency compatibility
  • Expandable runtime is supported with optional BP24V9RM Series for extended backup requirements
  • Intelligent battery management system with temperature-compensated charging with advanced 4-stage battery charging algorithm extends battery life
  • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
  • Rack mount and tower mount kits included for both Battery pack and UPS module
  • Adjustable telescopic rail kits suit any depth of the rack
  • LED / LCD display panel rotates for viewing in rackmount or tower configurations
  • Network-grade AC surge and noise suppression
  • External battery packs are field replaceable and hot swappable

Package Includes

  • MU1000RM2U, 1KVA  2U power module
  • Four post compatible, telescopic adjustable rack rail kit -2 sets
  • Tower stands for upright tower configuration
  • RS232 cabling and CD
  • User manual

Specifications

INPUT DATA
Rated input current (Maximum Load) 4.99Amp
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
UPS Input Connection Type IEC C14 inlet
UPS Input Connection Description 230/220/240V (L,N,PE) input wiring, 50/60Hz
Recommended Electrical Service 5Amp
Input Phase Single-Phase, 3W system (L,N,PE)
OUTPUT DATA
Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1KVA
Output Watt Capacity (Watts) 1000
Output kW Capacity (kW) 1KW
Output Capacity Details Supports up to 110% load continuously in double conversion mode, 111 to 125% for 12minute, 126% to 150% for 55 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor 1
Crest Factor 3:01
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details Voltage selection via front panel LCD interface
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacle Details 6no of IEC C13
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
VOLTAGE REGULATIONS & SURGE DATA
Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction Corrects over voltages up to 300V
Undervoltage Correction Corrects under voltages as low as 110V
UPS AC Suppression Joule Rating 655
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
BATTERY DETAILS
Full Load Runtime (min.) 5min. (1000W)
Half Load Runtime (min.) 12.5 min. (500W)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility BP24V18RT2U, BP24V27RT2U,BP24V36RT2U,BP24V72RT3U
DC System Voltage (VDC) 24V
Battery Recharge Rate (Included Batteries) Less than 5 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description Hot-swappable, user replaceable external battery packs
Expandable Runtime Yes, with additional battery packs
Transfer Time 0mSec in online, double-conversion mode
Low Voltage Transfer to Battery Power 110V
High Voltage Transfer to Battery Power 300V
USER INTERFACE AND CONTROLS
Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions;
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
PHYSICAL DETAILS
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Included Mounting Accessory Description 2 sets of adjustable 4 post rack rails included; 2-9U STAND tower kit included
Primary Form Factor Rackmount or Tower mount
UPS Power Module Dimensions (HWD in mm) 89 x 440 x 375
Rack Height 2U
UPS Dimensions Details Includes 2U UPS/power module
Included Battery Pack Weight (kg) 11kgs + 3kgs for rail kits
Shipping Dimensions (HWD in mm) 169 x 50.29 x 430
Shipping Weight (kg) 18kgs
Cooling Method Smart Fan with variable speed based on temperature
UPS Housing Material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 235
AC Economy Mode BTU / Hr. (Full Load) 125
Battery Mode BTU / Hr. (Full Load) 315
AC Mode Efficiency Rating (100% Load) 94%
AC Economy Mode Efficiency Rating-full Load 98%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 40 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Communications Interface RS232/DB9 Serial; Slot for SNMP/Web interface
Software compatible Windows family all versions, Linex, Sun Network OS, IBM Aix, Compaq Tru64 SGI IRIX, FreeBSD, HP-UX and MAC
Network Management Cards SNMP-UP1
UPS monitoring Software Supplied along with UPS. Optional SNMP card with web based available on request
Network Surge RJ45 I/O ports available for network or FAX/Modem
Communications Cable USB & DB9 serial
CERTIFICATIONS & WARRANTY
UPS Certifications CE, EN/IEC 62040-1:2008, EN/IEC 62040-2:2006, EN/IEC 61000-3-3:2013, EN/IEC 61000-3-2:2014
UPS Quality standards ISO9001:2015, ISO14001:2015, RoHs
Product Warranty Period (Worldwide) 2-years limited warranty

Similar Products

MU2000RM3U

Magnizon MU2000RM3U 2000VA / 2000 watt Smart online, double-conver...

MU2000RM2U

Magnizon MU2000RM2U 2000VA / 2000 watt Smart online, double-conversi...

MU3000RM3U

Magnizon MU3000RM3U 3000VA /3000 watt Smart online, double-conversion ...

MU3000RM2U

Magnizon MU3000RM2U 3000VA /3000 watt Smart online, double-conversio...

MU6000RM3U

Magnizon MU6000RM3U 6000VA / 6000 watt Smart online, double-conversi...

MU10KRM3U

Magnizon MU10KRM3U 10kVA / 10000 watt Smart online, double-conve...

Optional Products