Magnizon’s HG series is a Smart DC-to-AC inverter with auto line-to-battery transfer and integrated Battery charge, serving as an extended run UPS, a standalone power source or an automotive inverter. HG series Smart inverter supplies power from AC power and DC source. When AC cable is connected to a wall socket, utility power goes to connected equipment(s) and/or charges the battery set via charging system. In battery mode, Smart inverter automatically converts battery energy into AC power for backing up the connected devices. Large LCD displays real time information along with operational schemes, and can also display error codes for easy repair and maintenance. Reliable transformer less IGBT based design and frequency controlled power, very much compatible to all domestic loads: refrigerators, TV’s, Computers, and power tool and battery chargers. Smart micro controller based 3-stage built in charging system properly charge and maintain battery bank.
Well designed for applications where grid power is not stable or brownouts.
Versatile inverter/charger with PWM Sine wave system with seamless transfer switching serves as an automotive inverter for RVs, trucks, standalone alternative power source with high end back up times with various battery technologies (VRLA, GEL, Deep cycle and many more)
Perfectly suitable for Off-grid and Hybrid applications using additional MPPT controller
Small PV plants for houses/villas and small offices.
Remote closets and small computer room applications.
12V DC or 220/230/240V AC input; 220/230/240V, 50 /60Hz output
500VA continuous output with double boost capacity.
Microprocessor controlled Smart volume design
Built in 8~15A Smart Utility based battery charger
PWM Sine wave output
Automatic line-to-battery switchover
High efficient DC-to-AC conversion, minimizing energy loss
Rack design & wall-mounted design for flexible installation
Intelligent 3-stage charger control for efficient charging and preventing overcharge of battery
Auto restart while AC recovery
User-friendly LCD+LED indications
Multiple protection: low battery alarm, low battery shutdown, over
charged protection, overload protection, over temperature protection, short circuit protection
With the environmental temperature control charge management
Quiet, high efficiency operation, high surge capacity and low idle current
CE Safety
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload, over temperature and battery deep discharge protection
Cold start function
Rated Power | 500VA |
Nominal Input Voltage | 220/230/240V AC |
Low Loss Voltage | 170V AC +/- 7V (UPS mode) |
Low Loss Voltage | 90V AC +/- 7V (Appliance mode) |
Low loss return Voltage | 180V AC +/- 7V (UPS mode) |
Low loss return Voltage | 100V AC +/- 7V (Appliance mode) |
High loss Voltage | 280VAC +/- 7V |
High loss Return Voltage | 270VAC +/- 7V |
Max AC input voltage | 300V AC |
Frequency Range | 50Hz/60Hz (auto sensing) |
Low loss frequency | 40+/-1Hz |
Low loss return frequency | 42+/-1Hz |
High loss frequency | 65+/-1Hz |
High loss return frequency | 63+/-1Hz |
Efficiency | >97% |
AC Voltage Regulation | 230V AC +/- 5% |
Rated Output Power | 500VA/400W |
Output Voltage Waveform | PWM Sine wave |
Output Frequency | 50Hz/60Hz (auto sensing) |
Surge Power | 1000VA |
Efficiency | 95-97% |
Over Load protection | 5sec @>150% load; 10sec@110~150% load |
Nominal DC input Voltage | 12V DC |
Cold Start Voltage | 11.5V DC |
@load < 20% | 11.0V DC |
@ 20% < load < 50% | 10.7V DC |
@ load > 50% | 10.1V DC |
@load < 20% | 11.5V DC |
@ 20% < load < 50% | 11.2V DC |
@ load > 50% | 10.6V DC |
@load < 20% | 10.5V DC |
@ 20% < load < 50% | 10.2V DC |
@ load > 50% | 9.6V DC |
High DC Recovery Voltage | 14.5V DC |
High DC Cut-off Voltage | 15.5V DC |
No Load Power Consumption | <10W |
Saving Mode Power Consumption | <5W |
Transfer Time | 6-10mSec |
Efficiency | 90~93% |
Battery Voltage | 12V DC |
Floating Charge Voltage | 13.5V DC |
Overcharge Protection | 15.5V DC |
Maximum Charge Current | 8~15Amp |
Bulk Charging Voltage (Flooded Battery) | 14.6V DC |
Bulk Charging Voltage (AGM/GEL battery) | 14.1V DC |
Charging Algorithm | 3-Stage (CC-CV-Floating) |
AC/DC mode | Displays output power, Output Voltage etc |
Battery Mode | Yes. Battery symbol flickers every one sec |
Battery | Displays Battery charge status |
Fault | Displays fault codes (refer the service manual) |
Low Battery at Battery Mode | Sounding every 2 seconds |
Over Load | Sounding every 0.5seconds |
Faults | Continuous sounding |
Battery deep discharge Protection | Yes |
Battery Over charge protection | Yes |
Inverter Over load protection | Yes |
Over temperature protection | Yes |
Dimension (WxHxD-mm) | 224*255*80mm |
Net Weight (kgs) | 1.9Kgs |
Humidity | 5% to 95% Relative Humidity (non-condensing) |
Operating Temperature | 0degC to 40deg C |
Storage Temperature | -15degC to 50degC |
Noise Level | less than 50dB |
Quality/Safety standards | ISO9001:2015/ISO14001:2015 |
Safety | EMC/CE/ROHS |
Disturbance at Mains Terminals | EN61000-6-3:2007+ A1: 2011+ AC:2012 |
Radiated Disturbance | EN61000-6-3:2007+ A1: 2011+ AC:2012 |
Harmonic Current Emission | EN61000-3-12: 2011 |
Voltage fluctuations & flickering | EN61000-3-11: 2000 |
Electrostatic Discharge (ESD) | IEC 6100-4-2:2008 |
Radio-frequency & continuous radiated disturbances | IEC 6100-4-3:2006 + A1:2007 + A2:2010 |
EFT/B Immunity | IEC 6100-4-4:2012 |
Surge immunity | IEC 6100-4-5:2014 |
Conducted RF immunity | IEC 6100-4-6:2013 |
Power frequency magnetic field | IEC 6100-4-8:2009 |
Voltage DIP | >95% reduction,IEC 6100-4-11:2004 |
Voltage DIP | >30% reduction,IEC 6100-4-11:2004 |
Voltage Interruption | IEC 6100-4-11:2004 |