Magnizon OG-12K-DM String Inverter is the ideal solution for commercial & industrial usage. Parallel capability upto 100nos allows to simply up the scalability and enhancing the overall plant capacity. With the characteristics of dual independent input sections with two independent MPP trackers, wide MPPT tracking range, True three phase transformer-less design, IP65 harshest industrial grade protection level, convectional cooling system and embedded RS485, WIFI and optional SNMP interface, it forms Magnizon Trio String Inverter an ideal solution for medium and large PV Power Station.
Full data display and communications
Cost advantages
Max. DC input power | 18000W |
Max.DC input voltage | 1000Vdc |
Max. Input Current | 33A (3x11A) |
MPPT tracking voltage range | 160-950Vdc |
MPPT operating voltage range (full load) | 470-850V |
Min. / start DC voltage | 200 / 250Vdc |
Number of MPPT tracking | 2 |
Maximum number of PV strings | 3(2/1) |
Rated AC active power | 15KW |
Max. AC active Power (Pf=1) | 16.5KW |
Max. AC apparent power | 16.5KVA |
Rated output voltage | 380/400/415Vac |
AC output topology | 3Ph+N+PE |
Output voltage range | (1±15%) x Normal AC Voltage (adjustable ±5%,±10%,±15%,±20%) |
Gird frequency range | 50/60Hz(±4.5Hz), (adjustable) |
Max. AC output current | 23A |
Power factor (cos?) | (0.8 leading ? 0.8 lagging) (adjustable) |
Total harmonic current distortion?THDi? | <2% |
DC Current Injection | <0.5% In |
Input DC switch | YES |
Anti-islanding protection | YES |
AC overcurrent protection | YES |
AC short circuit protection | YES |
DC reverse connection | YES |
Anti-surge protection | YES |
Insulation resistance detection | YES |
Leakage current protection | YES |
Intelligent reactive power regulator | YES |
PID | YES |
Topology | Transformer less |
Max. efficiency | >98.8% |
Euro efficiency | >98.4% |
MPPT efficiency | >99% |
Standby(night time) losses | <10W |
Front Panel | LED/LCD Display |
Cooling | Natural Cooling |
Communication interface | RS485, USB, Ethernet, WIFI(optional), GPRS(optional) |
Warranty | 5years(optional 10/15/20years) |
Operating temperature | -25.0 to 60.0 °C |
Humidity range | 0-99% (non-condensing) |
Altitude | 4000m |
Noise level | <30dB |
Protection rating | IP65 |
Dimension W×L×D (mm) | 385mm*490mm*190mm |
Net Weight (kg) | 21.8Kgs |
Grid Code | NB/T32004, VDE-AR-N 4105, IEC 61727 |
Safety/TUV | IEC62109-1, IEC62109-2 |
EMC | EN 61000-6-2 , EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12 |
Quality Standards | ISO9001:2015, ISO14001, RoHs |